An assessment is set up in the Configuration tab of the GUI.

cassy-fatigue gui                          # new, empty assessment
cassy-fatigue gui my_assessment.yaml       # continue an existing one

If the cassy-fatigue command is blocked (for example by IT restrictions) or not found, run it through Python instead (note the underscore):

python -m cassy_fatigue gui
python -m cassy_fatigue gui my_assessment.yaml

On Windows, cassy-fatigue-gui starts it without a console window.

The editor

  • Pages on the left: General, Analyses, Materials, Regions, Loads, Fatigue events, Run. Work through them from top to bottom.
  • Validation banner at the top, updated after every edit. It shows the first problem in the configuration, or turns green when the configuration is complete. Checks that need the result data (meshes, units, material coverage) still run when the assessment starts.
  • Log at the bottom: result reads and their duration, the DPF server, run progress and errors.
  • File menu: New, Open…, Save, Save As…, Open results… (Ctrl+R).

The assessment is saved as a configuration file (.yaml). You can save an incomplete one as a draft and continue later. File paths are stored relative to the configuration file, so you can move a folder with the configuration and its result files together.

When you add a result file or open a configuration, the editor reads the file's metadata in the background (busy indicator in the status bar) and uses it to fill its dropdowns: result sets with their times, material IDs, named selections, whether the file contains temperatures, element types and the unit system. It reads the whole mesh, so this can take minutes for a large model.

General

  • Design code: SDC-IC, RCC-MRx or RCC-MR.
  • Material library: optional folder with additional or modified CASSY material files. It follows CASSY's usual rules for overriding bundled materials.

Analyses

Add… adds one or more Ansys result files (.rst, .rth). Each gets a short name, used by the loads; double-click it to rename it. Select a row to see the file's mesh, result sets and named selections below the table.

All analyses must use the same mesh: same node IDs and coordinates, and for structural .rst files also the same elements and material IDs. This is checked when the run starts.

The Metadata column summarises the file and flags problems: NO UNITS RECORDED, NO SOLID ELEMENTS, non-solid elements that will be ignored, or a structural file without stresses. Re-read metadata reads the file again, for example after a re-solve.

Temperatures

The temperature used for an event at a node is the maximum over all result sets used in its loads, also those subtracted. Temperatures are never added or subtracted.

By default each set takes the temperature stored in its own .rst file (the structural body temperatures, BFE); the Temperature column shows own. In a load +op:3, −start:3 the temperature is therefore the maximum of op set 3 and start set 3.

If a structural result does not contain the temperatures, typically because they come from a separate thermal analysis, add the thermal .rth as an analysis too, select the structural row and click Temperature… to choose it as the source. The column then shows from <analysis>.

Each structural set is matched to the set of the source with the same time in seconds. If no set or several sets of the source have that time, the run stops. Matching by set number alone is never done. Sources without temperatures are marked in the dialog, and the run stops at the start if one is chosen. traceability.json records which source was used for each analysis.

Units

Stresses, temperatures and coordinates are converted to Pa, °C and m, using the unit system recorded in each result file; the Units column shows from result. If a unit is unknown, the run stops rather than guessing.

A result solved without a unit system (for example MAPDL without /UNITS) records no units and is flagged NO UNITS RECORDED. Select it, click Units… and choose the units the model was solved in:

Quantity Allowed units
Length m, mm, cm, in, ft
Stress Pa, kPa, MPa, GPa
Temperature degC, C, K, degF
Time s

Declarations only fill in units the result does not record. If the result records a unit and your declaration differs, the run stops instead of overriding it. Declare the units of each analysis separately, including a temperature source. traceability.json records, for each analysis, the units used and whether they came from the result or from your declaration.

Materials

Assign a CASSY material to every part of the model, by solver material ID or by named selection. See Material assignment.

Regions

Optional named selections with a welding factor (welding_f) and a dose (dpa). Pick the selection from the dropdown (nodal or elemental selections of the first structural analysis) and enter the values.

Nodes outside every region use welding_f = 1 and dpa = 0. Regions must not overlap. The welding factor must be at least 1 and dpa non-negative. Regions are independent of the material assignment.

Loads

A load is one stress range that you have identified, for example the range between cold shutdown and hot operation. Each row has:

  • Name, used by the events (double-click to rename; events are updated).
  • Class: P (primary) or Q (secondary). This is your engineering judgement; it is not derived from the results.
  • Sets: the result sets, each added (+) or subtracted (−). Double-click (or Edit sets…) to edit them: each row is a sign, an analysis and a result set. The dropdown shows each set with its time and load step/substep, for example set 2: t=2 s, LS2/SS1.
  • Scale: optional factor, default 1.

The stress tensor of the load is scale × (σ(set a) − σ(set b) + …), the same structure as a load on a CASSY path.

  • Set numbers are the result set numbers as listed by Ansys (1, 2, 3, … over all load steps and substeps), not load step numbers.
  • Sets from different analyses can be combined in one load. Each set may appear only once in a load.
  • Add one per set… creates a +analysis:set load for every set of an analysis, a quick start when each result set is already a stress range from a reference state.

Do not count a stress twice

Each load should be the range you intend. If a result set already contains, for example, the pressure stress, do not also add a separate pressure load to the same event.

Fatigue events

An event is a cycle type that occurs ncycles times. Each row has an ID, the number of cycles and the loads it combines (double-click, or Choose loads…, to tick them). Its stress range is the sum of these loads.

For each event and node:

  • the total range Δσ is the sum of all its loads, and the primary range Δσ_P the sum of its P loads only;
  • the equivalent (von Mises) stress ranges are computed from these summed tensors;
  • CASSY computes the allowable cycles N, and the usage is Vj = ncycles / N.

The total usage is U_total = Σ Vj over all events. Events are listed as you define them: there is no automatic cycle counting or rainflow. Loads cannot be subtracted in an event: to use a range the other way round, define a load with the opposite signs.

Run

Save and run saves the configuration and runs the assessment. Reports go to the Output folder shown (default: <configuration name>_results next to the configuration file). Existing reports are replaced only if Overwrite existing reports is ticked.

While the run is going, the page shows a progress bar, the current step, the elapsed time and a rough estimate of the remaining time. The estimate assumes all steps take equally long, and DPF cannot report progress within a single read, so treat it as an indication only.

Cancel stops the run at the end of the current step. No reports are written and existing reports are left as they were. The window cannot be closed while a run is going: cancel it first.

When the run finishes, its results are loaded into the Results tab. Show results switches there and Open output folder opens the reports. See Results viewer and Results.

DPF server

DPF reads results through a server process. The Run page chooses the server for the session:

  • Start a local server (default): started on the first result read and shut down when you close the window or click Release DPF server. Starting takes a few seconds, plus the license checkout on the first read. Ansys installation selects the installation if DPF does not find the right one (see Locating Ansys).
  • Connect to an existing server at an IP address and port. The GUI never shuts down a server it did not start.

The result files must be readable by the DPF server. The connection is unencrypted, so only connect to servers on your own machine or a trusted network.