Skip to content

Results

Every run writes three files to the output folder.

fatigue.vtu

The solid mesh of the model, with the original node and element IDs, coordinates in metres, and these values at every node:

Field Meaning
U_total Total usage, the sum of Vj over all events
invalid_code 0 if the node is valid, otherwise the flags of all events combined
material_id_U The material that governs U_total at this node
Vj_<event> Usage of the event, ncycles / N
N_<event> Allowable number of cycles
delta_sigma_eq_Pa_<event> Equivalent (von Mises) total stress range, Pa
delta_primary_eq_Pa_<event> Equivalent primary stress range (P loads only), Pa
T_degC_<event> Temperature used, °C (maximum over the event's sets)
de1_<event> … de4_<event>, de_total_<event> Strain-range components and total strain range from CASSY
welding_f_<event>, dpa_<event> Welding factor and dpa used
invalid_code_<event>, material_id_<event> Flags and governing material of this event

<event> is the event id, for example Vj_startup. Open the file in the results viewer or in ParaView.

For stress-based SDC-IC curves the strain fields are not applicable and may be empty (NaN) even though N and Vj are valid.

Invalid nodes

A node is invalid for an event when it cannot be assessed. Its N, Vj and U_total are then NaN (shown magenta in the viewer), and the flags say why. Flags add up: 3 means 1 + 2.

Flag Reason
1 Stress missing or not finite
2 Temperature missing or not finite
16 CASSY could not compute a positive N: typically a property outside its temperature range, or a strain or stress range above the fatigue curve
32 A material property needed by the code is missing

If any event is invalid at a node, its U_total is NaN as well. An invalid event is never left out of the sum, because that would understate the usage. Review invalid nodes as part of the assessment: they often point to temperatures outside the material data or to stress singularities.

Nodes on a material interface

A node shared by two materials is assessed once per material (see Material assignment). The file reports the material with the higher total usage, and all per-event fields of that node come from the same material, so the Vj values always add up to U_total. material_id_U tells you which material that was. If one material is invalid at the node, the node is reported invalid even if the other material has a finite result.

configuration.yaml

The configuration exactly as it was used, with the file paths resolved. Keep it with the results.

traceability.json

Everything needed to audit or reproduce the run:

  • versions of cassy-fatigue, CASSY and DPF, and hashes of the CASSY and cassy-fatigue source files;
  • the material files used, with their hashes, and the material assignment (in named-selection mode: which assignment number is which selection);
  • the units of each analysis and whether they came from the result or the configuration (analysis_units);
  • the temperature source of each analysis (temperature_sources);
  • non-solid elements that were skipped, per element type (skipped_elements);
  • the DPF server used, the meaning of the invalid flags and the known limitations.

Interpreting a run

A run that finishes has written its reports. Whether the component passes is your judgement: check the maximum U_total, the invalid nodes, the material assignment and the limitations. Hotspots at sharp corners and other stress singularities depend on the mesh. Judge them like any other peak stress.