Skip to content

Configuration file

Advanced

Most assessments are set up in the GUI, which writes this file for you. This page is for users who write or generate configuration files by hand, for example for scripted or batch runs from the command line. The meaning of every entry is explained in Setting up an assessment; this page only gives the file syntax.

An assessment is one YAML file. A complete example:

code: SDC-IC
analyses:
  struct: model.rst
materials:
  1: SS316L(N)-IG_SDC-IC
loads:
  pressure: {classification: P, sets: [+struct:1]}
  heatup:   {classification: Q, sets: [+struct:3, -struct:2]}
fatigue_events:
  - {id: startup, ncycles: 30000, loads: [pressure, heatup]}
  - {id: thermal, ncycles: 1000,  loads: [heatup]}
regions:
  - {named_selection: WELD_A, welding_f: 1.5, dpa: 0}
Entry Meaning GUI page
code Design code: SDC-IC, RCC-MRx or RCC-MR General
material_library Optional folder with additional or modified CASSY material files General
analyses Your result files, each under a short name you choose Analyses
materials Which CASSY material applies to which part of the mesh Materials
regions Optional welding factor and dpa for named selections Regions
loads Named stress ranges, each classified P or Q Loads
fatigue_events The events: which loads they sum and how many cycles Fatigue events

File paths are relative to the YAML file. The file is checked strictly: misspelled or unknown keys, duplicate keys, references to undefined loads and duplicate event IDs stop the run with a message, before any result is read.

Analyses

analyses:
  op: operation.rst
  start: startup.rst
  therm: thermal.rth

An entry can also be written in long form, to declare units or a temperature source:

analyses:
  mech:  {file: mechanical.rst, temperature: therm, units: {length: mm, stress: MPa}}
  therm: thermal.rth

units accepts length, stress, temperature and time, with the values listed in Units. temperature names another analysis; without it, each .rst uses its own temperatures.

Materials

By solver material ID (integer keys):

materials:
  1: SS316L(N)-IG_SDC-IC
  2: CuCrZr-IG Tr B SDC-IC

By named selection (selection names as keys, spelled exactly as in the result file):

materials:
  STEEL_BODY: SS316L(N)-IG_SDC-IC
  COPPER_BODY: CuCrZr-IG Tr B SDC-IC

The two forms cannot be mixed. In named-selection mode the assignment numbers in the results follow the order of the entries. See Material assignment.

Regions

regions:
  - {named_selection: WELD_A, welding_f: 1.5, dpa: 0}
  - {named_selection: FIRST_WALL, welding_f: 1, dpa: 2.5}

Loads

loads:
  heatup:
    classification: Q              # P (primary) or Q (secondary)
    sets: [+struct:3, -struct:2]   # stress of set 3 minus stress of set 2
    scale: 1                       # optional factor, default 1

struct:3 means result set 3 of analysis struct. Every set needs an explicit sign. Sets of different analyses can be combined ([+op:3, -start:3]); each set at most once per load. scale must be finite and non-zero.

Fatigue events

fatigue_events:
  - id: startup
    ncycles: 30000
    loads: [pressure, heatup]

Loads are listed without signs, each at most once.