Troubleshooting¶
The run stops with a message in the log whenever something is unclear or inconsistent. It does not guess. The validation banner of the editor catches most configuration problems before you run. The most common messages:
Configuration and materials¶
Output files already exist in …; use --overwrite explicitly- A previous run wrote reports to the same folder. Choose another output folder, or tick
Overwrite existing reports on the Run page (command line:
--overwrite). Unknown CASSY material '…'- The name does not match a CASSY material exactly, typically in a configuration file edited by hand or a material library that is no longer selected. Pick the material from the dropdown on the Materials page, or check the Material library on the General page.
Material '…': …(refused material)- The material's fatigue curve needs arguments a nodal assessment cannot provide (mean stress, Inconel options), or it is stress-based and the code is RCC-MR/RCC-MRx. Such materials are greyed out in the dropdown. See Material assignment.
CASSY is not array-aware …- The installed CASSY is too old. Install a CASSY version with array support in the same environment.
Result files¶
Analysis X records no length unit …(or stress, temperature, time)- The result was solved without a unit system (flagged
NO UNITS RECORDEDon the Analyses page). Declare the units it was solved in with Units…, see Units. Analysis X records stress unit 'MPa' but the configuration declares 'Pa'- Your unit declaration contradicts the file. Reset it to (from result) with Units…: the units recorded in the file are used.
Analysis X has no result set N- Set numbers are result set numbers over all load steps and substeps, starting at 1. The set dropdown of Edit sets… lists the existing sets with their times. If the result was re-solved, use Re-read metadata.
Analysis X (temperature source of Y) contains no BFE (structural) temperatures …- The
.rsthas no temperatures. Take them from the thermal analysis with Temperature…, see Temperatures. Temperature source X of Y must have exactly one set at time t; found 0- Each structural set needs a thermal set with exactly the same time in seconds. Check that the thermal analysis saves results at the times of the structural one.
Analysis X does not have the same node IDs as …,… incompatible element connectivity/material IDs- All analyses must use the same mesh. Check that the results come from the same model.
The mesh contains no solid elements- Only solid elements are assessed. Shells, beams, contacts and other non-solid
elements are skipped (and counted in
traceability.json), but at least one solid element is needed.
Material selections¶
Material named selections leave N solid elements unassigned,… overlaps another assignment at N elements- In named-selection mode the selections must cover every solid element exactly once.
Material selection '…' contains no complete elements- A nodal selection only assigns elements whose nodes are all selected. A surface selection therefore assigns nothing. Use a body (elemental) selection.
DPF server¶
- The server does not start
- Check that Ansys with DPF is installed and licensed on this machine. If DPF does not
find the installation, or finds the wrong one, choose it under Ansys installation
on the Run page (command line:
--ansys-path); see Locating Ansys. - Cannot connect to an existing server
- Check that the server runs at the IP address and port given on the Run page (command
line:
--dpf-ip/--dpf-port) and that the result files are readable from the server's machine.
Results¶
- Many invalid nodes (flag 16)
- CASSY could not compute
N, typically because the temperature is outside the range of the material data or the strain range is above the fatigue curve. Look atT_degC_<event>and the stress ranges of those nodes in the node report. - Invalid nodes with flag 2
- No temperature at those nodes for at least one set. Check the temperature source.