Skip to content

Supported MCNP input

llevant reads MCNP inputs through migjorn, and follows MCNP 6.2 wherever the two could differ: it has been checked point by point against MCNP itself (how).

Geometry

  • Surfaces:
    • P (4 coefficients or 3 points), PX/PY/PZ, SO/S/SX/SY/SZ;
    • C/X/C/Y/C/Z and CX/CY/CZ;
    • K/X/K/Y/K/Z and KX/KY/KZ (one or two sheets);
    • SQ, GQ;
    • TX/TY/TZ, including degenerate A = 0;
    • X/Y/Z by points;
    • periodic surfaces (n -m type ...).
  • Macrobodies RPP, BOX, SPH, RCC, TRC, RHP/HEX, REC, ELL, WED and ARB, as whole bodies or facets n.k.
  • Transforms and cell forms:
    • TRn/*TRn (3, 9, 12 or 13 entries, m = ±1);
    • inline FILL transforms and *FILL;
    • TRCL/*TRCL, inline or by number;
    • U and nested fills, at any depth;
    • complements #n and #( );
    • LIKE n BUT.
  • Lattices LAT=1 (any parallelepiped) and LAT=2 (hexagonal prisms), 2-D or 3-D:
    • filled uniformly or by a fill array, with nR repeats and per-element transforms;
    • elements may be filled by the lattice cell itself.
  • MCNP's own restrictions (skewed one-sheet cones and tori, macrobodies with vectors that are not at right angles…) make the cell unsupported, as MCNP would refuse it. llevant info lists them; points that only such a cell could hold are labelled unsupported.

Not read

  • Cell parameters on data cards. IMP, U, FILL, TRCL and LAT are read from the cell cards only. A data card that gives them for every cell (IMP:N 1 1 1 0) is reported as a diagnostic, and the geometry may then differ from MCNP's: put these parameters on the cell cards.
  • READ cards. The files they name are not read; this too is reported as a diagnostic. Assemble the input into one file first.

llevant info model.i lists every diagnostic with its line.

Results files (--field)

File What is drawn
CSV values per cell, material, cell instance or repeated-structure path
MCNP meshtal (FMESH) the mesh, exactly as the FMESH card in the input places it, TR= included
D1SUNED cuvmsh (out=cuv) each voxel's flux
MCTAL F4, F6, F7 and F8 cell tallies, per cell or per cell instance

Not drawn yet: surface tallies, point detectors, and each cell's own flux inside a cuvmsh voxel. Details: Fields.

Labels

Every point is given a status:

Status Means
inside in exactly one cell
gap in no cell: MCNP would lose a particle here
overlap in more than one cell
on-surface on a surface, within the tolerance (1e-8 cm by default)
unsupported in no cell but possibly an unsupported one (see the diagnostics)
too-deep universes nested deeper than llevant follows (64 levels)